Fast, Reliable Water Content Determination with EVA Karl Fischer Titrators

Accelerate time-to-result, reduce operator exposure, and ensure audit-ready compliance across environmental, chemical, food, and pharmaceutical laboratories.

From METTLER TOLEDO – global leader in analytical instrumentation.

Designed for Laboratories Where Moisture Accuracy is Critical

Environmental testing laboratories

Environmental Testing Laboratories

Accurate moisture analysis for soil and water testing workflows

Chemical manufacturing plants

Chemical Manufacturing Plants 

Maintain product consistency and process control

Food & beverage production

Food & Beverage Production

Protect product quality and shelf-life stability

Pharmaceutical QC laboratories

Pharmaceutical QC Laboratories 

Enable compliant and repeatable moisture analysis

Contract testing labs

Contract Testing Labs 

Deliver reliable results across diverse sample types

Why Water Content Matters

Accurate water determination is essential for: 

  • Maintaining product quality and shelf life 
  • Ensuring process consistency in manufacturing 
  • Meeting regulatory and compliance requirements 
  • Delivering reliable results in contract testing 

Inaccurate water analysis can lead to batch failures, compliance risks, and costly rework. 

Where Older / Traditional / Conventional KF Systems Fall Short 

Many laboratories still face: 

  • Slow titration times limiting throughput 
  • Difficulty analysing complex or challenging samples 
  • Handling of chemicals increasing variability and errors 
  • Exposure to hazardous Karl Fischer reagents 
  • Disconnected systems complicating data management 

EVA Karl Fischer titrators are designed to eliminate these challenges by combining speed, precision, automation, and compliance in a single, integrated platform. 

Core Benefits

EVA_C3_KF_Titrator_InMotion_Pro_Solid_Sample_Measurement_

Faster Results Without Compromising Accuracy

  • Fast time-to-result enabled by FFA™ control algorithm technology, maintaining optimal reagent concentration for efficient reaction rates 
  • High dispensing resolution (up to 120,000 steps) for precise titration control 
  • Rapid, interference-free measurement using a digital sensor (dSens M143) 
EVA_C3_KF_Titrator_XPR_Balance_Benchtop_Setting

Streamlined Workflows and Higher Throughput

  • Automatic sample detection and titration start 
  • Direct balance integration for accurate, automatic weight transfer 
  • OneClick™ operation for fast access to routine methods 
  • Autosampler compatibility (InMotion KF) for high-throughput environments 
EVA_V3_With_dPump

Safer Operation in the Laboratory

  • Automated solvent management (dPump KF) reduces operator exposure to hazardous reagents 
  • Automatic solvent exchange and emptying functions 
  • Remote operation outside the fume hood using an extended terminal cable (2.5 m) 
EVA_V1V3_withLabX

Compliance-Ready Data Integrity

With LabX™ software integration: 

  • Centralised data management and workflow control 
  • Electronic signatures and audit trails 
  • Support for 21 CFR Part 11 and ALCOA++ requirements 
EVA_KF_Coulometric_Titrator_InMotion_Pro_Service

Reliable Performance You Can Depend On

  • Swiss-engineered system designed for durability and long-term use 
  • Modular components for easy maintenance and servicing 
  • Consistent performance across simple and challenging sample types 

Why EVA Stands Out 

Modern laboratories require more than accurate titration. They need speed, safety, and data integrity built into every workflow. 

EVA Karl Fischer titrators deliver:

  • Faster time-to-result through advanced control algorithms 
  • Integrated digital workflows with secure data management 
  • Reduced operator risk through automation 
  • Seamless integration with laboratory systems 
  • Audit-ready processes for regulated environments 

Choose the Right System for Your Application 

EVA Volumetric Titrators (V1 V3)

EVA Volumetric Titrators (V1 / V3)

Ideal for:

  • Liquids and soluble solids 
  • Complex or challenging sample matrices 

Key capabilities:

  • Advanced FFA™ control technology 
  • High-precision dispensing (120,000 steps) 
  • Fast-response digital sensor 
  • Next-generation burette design with low dead volume 
  • Automated solvent management system 
EVA Coulometric Titrators (C1 C3)

EVA Coulometric Titrators (C1 / C3)

Ideal for:

  • Trace-level water determination 

Key capabilities:

  • High sensitivity for low-level water detection 
  • Innovative cell design for easier cleaning and reduced contamination risk 
  • Flexible modular setup with plug-and-measure components 
  • Automation support with autosampler compatibility 


EVA Volumetric Titrators (V1 V3)See EVA in Action

Experience faster, safer, and more accurate water determination in your own lab. Discover how EVA streamlines workflows, reduces risk, and improves results from day one.

Aoife McNicholas - Technical Sales Specialist

Talk to an Application Specialist

Get expert advice on selecting the right EVA system for your application.
Our specialists help you optimise performance, compliance, and throughput.

Full Lifecycle Services for Scientific Equipment

 

Download the EVA Product Brochure

Explore detailed specifications, features, and application capabilities of EVA Karl Fischer titrators—all in one place.

Mason Technology